Details
SPECIFICATIONS
Model |
SDG60S -3A6 |
SDG100S -3A5 |
SDG125S -3A6 |
SDG150S -3A6 |
SDG220S -3A7 |
||||||
Generator | |||||||||||
Type |
Dual Voltage | Dual Voltage | Dual Voltage | Dual Voltage | Dual Voltage (Manual parallel) |
||||||
Frequency | Hz | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
Prime Output | kVA | 50 | 60 | 80 | 100 | 100 | 125 | 125 | 150 | 200 | 220 |
Standby Output | kVA | 55 | 66 | 88 | 110 | 110 | 137.5 | 137.5 | 165 | 220 | 242 |
Voltage | V | 200/400 | 220/440 | 200/400 | 220/440 | 200/400 | 220/440 | 200/400 | 220/440 | 200/400 | 220/440 |
Power factor | % | 3-phase 0.8(lagging)/ Single-phase 1.0 | |||||||||
Engine | |||||||||||
Make/Model | ISUZU BB-4BG1T | ISUZU DD-6BG1T | HINO J08C-UP | HINO J08C-UP | KOMATSU SAA6D125E-2-B | ||||||
Type |
Direct-Injection, Turbo-Charged | Direct-Injection, Turbo-Charged | Direct-Injection, Turbo-Charged | Direct-Injection, Turbo-Charged | Direct-Injection, Turbo-Charged, Intercooled |
||||||
Rated output | kW(PS) | 48.1(65.4) | 87.4(57) | 73.6(100.1) | 91.2(124) | 96.3(131) | 153(113.6) | 118(160) | 140(190) | 178(242) | 204(277) |
Rated speed | min-1 | 1500 | 1800 | 1500 | 1800 | 1500 | 1800 | 1500 | 1800 | 1500 | 1800 |
Fuel tank capacity | L | 135 | 225 | 250 | 250 | 390 | |||||
Engine oil amount | L | 14 | 18 | 24.5 | 24.5 | 42 | |||||
Battery × quantity | 80D26R×1 | 95D31R×2 | 95D31R×2 | 95D31R×2 | 170F51×2 | ||||||
Dimension & Weight | |||||||||||
Overall length | mm(inch) | 2090(82.3) | 2600(102.4) | 2990(117.7) | 2990(117.7) | 3700(145.7) | |||||
Overall width | mm(inch) | 860(33.9) | 1000(39.4) | 1180(46.5) | 1180(46.5) | 1300(51.2) | |||||
Overall Height | mm(inch) | 1220(48.0) | 1400(55.1) | 1480(58.3) | 1480(58.3) | 1750(68.9) | |||||
Operating weight | kg | 1260 | 1870 | 2300 | 2430 | 3700 | |||||
Other | |||||||||||
Sound power level in decibels | dB | 86 | 90 | 88 | 91 | 90 | 92 | 92 | 94 | 93 | 95 |
Sound pressure level | dB(A) | 59 | 63 | 61 | 64 | 63 | 64 | 63 | 66 | 64 | 65 |
Designated emissions regulation | JPN Stage 2 | JPN Stage 2 | JPN Stage 2 | JPN Stage 2 | JPN Stage 2 |
- For other voltages except the above-mentioned ones, contact us. • Sound pressure level is measured at 7m in 4 directions average.
- Above figures are applied under operation in standard atmosphere conditions as per JIS D0006.
- "Standby Output" rating is applied only under intermittent or emergency operation for approximately 1 hour.