400KVA

400KVA

Category: Airman

Specifications
Details

SPECIFICATIONS

Model
SDG300S
-3A6
SDG400S
-3A6
SDG500S
-3A6
SDG610S
-3AK6
SDG610S
-3AV6
SDG800S
-3A6
Generator

Type
Manual parallelManual parallelManual parallelManual parallelManual parallelManual parallel
Dual Voltage            Dual Voltage            Dual Voltage            Dual Voltage            Dual Voltage            Dual Voltage
Power factor
Engine
Make/Model
%
3-phase 0.8lagging/ Single-phase 1.0
Type
KOMATSU SAA6D125E-2-B KOMATSU SA6D140E-3-A KOMATSU SAA6D140E-3-B KOMATSU SA6D170-A-1 VOLVO TAD1642GE KOMATSU SAA6D170E2-3
Direct-Injection,   Direct-Injection,   Direct-Injection,   Direct-Injection,   Direct-Injection,         Direct-Injection, Turbo-Charged,      Turbo-Charged,      Turbo-Charged,      Turbo-Charged,      Turbo-Charged,      Turbo-Charged,
Rated output Rated speed
Fuel tank capacity
Engine oil amount Battery × quantity
kW(PS)  2323162573503104213574853825204275804856605617635036845327236138347521022
Intercooled
Intercooled
Intercooled
Intercooled
Intercooled
Intercooled
min-1
L L
1500
1800         1500         1800         1500         1800         1500         1800         1500         1800         1500         1800
490
62
170F51×2
490
79
225H52×2
490
91.5
225H52×2
490
119
225H52×2
490
48
225H52×2
490
141
225H52×2
Dimension & Weight
Overall length Overall width Overall Height Operating weight
Other
mm(inch) mm(inch) mm(inch)
kg
3900153.5    4150163.4    4550179.1    4650183.1    4650183.1    5350210.6
140055.1     140055.1     160063.0     160063.0     160063.0     190074.8
176069.3     204080.3     209082.3     235092.5     235092.5     245096.5
4290                           5670                           6750                           7960                           6640                           9850
Designated emissions regulation         JPN Stage 2
JPN Stage 2
JPN Stage 2
JPN Stage 2

Model
SDG25AS
-3B1
SDG45AS
-3B1
SDG60AS
-3A6
SDG100AS
-3A6
SDG150AS
-3A6
Generator

Type
  Dual Voltage Dual Voltage Dual Voltage Dual Voltage Dual Voltage
Frequency Hz 50 60 50 60 50 60 50 60 50 60
Prime Output kVA 20 25 37 45 50 60 80 100 125 150
Standby Output kVA 22 27.5 40.7 49.5 55 66 88 110 137.5 165
Voltage V 200/400 220/440 200/400 220/440 200/400 220/440 200/400 220/440 200/400 220/440
Power factor % 3-phase 0.8lagging/ Single-phase 1.0
Engine
Make/Model   KUBOTA V2403-K3A KUBOTA V3800-DI-T-K3A ISUZU BB-4BG1T ISUZU DD-6BG1T HINO J08C-UD

Type
  Swirl chamber Direct-Injection, Turbo-Charged Direct-Injection, Turbo-Charged Direct-Injection, Turbo-Charged Direct-Injection, Turbo-Charged,
Intercooled
Rated output kW(PS) 19.126 23.732.2 3851.7 45.662 48.165.4 57.478 73.6100.1 91.2124 118160 140190
Rated speed min-1 1500 1800 1500 1800 1500 1800 1500 1800 1500 1800
Fuel tank capacity L 80 165 170 225 265
Engine oil amount L 9.5 84 14 18 24.5
Battery × quantity   80D26R×1 80D26R×1 80D26R×1 95D31R×2 95D31R×2
Dimension & Weight
Overall length mm(inch) 157061.8 199578.5 209082.3 2700106.3 3200126.0
Overall width mm(inch) 80031.5 95037.4 95037.4 114044.9 120047.2
Overall Height mm(inch) 109042.9 130051.2 130051.2 150059.1 163064.2
Operating weight kg 810 1215 1440 2,100 2,850
Other
Sound power level in decibels dB 80 83 79 82 80 83 81 84 85 88
Sound pressure level dB(A) 53 56 51 54 55 56 54 57 55 58
Designated emissions regulation JPN Stage 3 JPN Stage 3 JPN Stage 2 JPN Stage 2 JPN Stage 2
 
Frequency Hz 50 60 50 60 50 60 50 60 50 60 50 60
Prime Output kVA 270 300 350 400 450 500 555 610 555 610 700 800
Standby Output kVA 297 330 385 440 472.5 525 610.5 671 610.5 671 770 880
Voltage V 200/400 220/440 200/400 220/440 200/400 220/440 200/400 220/440 200/400 220/440 200/400 220/440
 
SPECIFICATIONS
SDG100AS
 


































 
 
  •  
Sound power level in decibels dB 95 98 95 99 96 99 98 102 101 104 99 102
Sound pressure level dB(A) 66 69 67 70 67 70 69 72 71 75 69 73
 
For other voltages except the above-mentioned ones, contact us.    • Sound pressure level is measured at 7m in 4 directions average.
  • Above figures are applied under operation in standard atmosphere conditions as per JIS D0006.
  • "Standby Output" rating is applied only under intermittent or emergency operation for approximately 1 hour.
 
  • For other voltages except the above-mentioned ones, contact us.    • Sound pressure level is measured at 7m in 4 directions average.
  • Above figures are applied under operation in standard atmosphere conditions as per JIS D0006.
  • "Standby Output" rating is applied only under intermittent or emergency operation for approximately 1 hour.
 

View more about 400KVA on main site